+86 13348028050
FD-MZ50ATKP KEYENCE FD-MZ50ATKP - Front View | Vcocnc FANUC Parts

KEYENCE FD-MZ50ATKP

Product information

SKU: FD-MZ50ATKP

Alternate: FDMZ50ATKP

Brand
KEYENCE
Part No.
FD-MZ50ATKP
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE FD-MZ50ATKP Product overview The KEYENCE FD-MZ50ATKP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Accessory: Instruction Manual, Connector cable (2.7 m 106.3" ) - Accumulated flow unit: 0.1/1/10/100/1000 (G, L) selectable - Ambient temperature: 0 to +50 °C 32 to 122 °F (No freezing) - Analog output: 4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value - Applied pressure range: Max. 145 PSI (1.0 MPa) - Conductivity of detection fluids: 5 µS/cm or higher - Connection port: NPT3/4 (20 A) - Control output/Accumulation pulse output/ Error alarm output: PNP open collector, max. 100 mA/ch *4 30 V or less, residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable) - Detectable fluids: Water or non-corrosive liquid - Detection fluid temperature: 0 to +85°C 32 to 185 °F (No freezing) - Display method: Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator - Display resolution: 0.1/1 (G/min, L/min) selectable - Environmental resistance / Enclosure rating: IP65 - Hysteresis: Variable - Integration data storage cycle: Save to memory every 10 seconds - Integration reset/bank switch input/flow zero function input: Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode - Material / Liquid end materials: Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM) - Memory backup: EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more) - Minimum flow volume: 0.7 G/min (2.5 L/min) *5 - Other materials: Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC - Possible display range: 0.7 - 26.4 G/min (2.5 - 100 L/min) *2 - Possible ranges to set: 0 - 26.4 G/min (0 - 100 L/min) - Power consumption (Current consumption): Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA) - Pressure loss: Max. 1.45 PSI (0.01 MPa) - Pressure resistance: 290 PSI (2.0 MPa) - Rated flow range: 0.7 - 13.0 G/min (2.5 - 50 L/min) *1 - Rating / Power voltage: 24 VDC, Ripple (P-P) 10 % or less, Class 2 - Relative humidity: 35 to 85 % RH (No condensation) - Repeatability: 0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S. *3 - Response time (chatter prevention feature): 0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable - Shape: Built-in amplifier - Type: Vertical - Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions - Weight: Approx. 1,130 g Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FD-MZ50ATKP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FD-MZ50ATKP
Brand
KEYENCE
Part Number
FD-MZ50ATKP
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Vertical
Shape
Built-in amplifier
Weight
Approx. 1,130 g
Accessory
Instruction Manual, Connector cable (2.7 m 106.3" )
Hysteresis
Variable
Analog output
4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value
Memory backup
EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)
Pressure loss
Max. 1.45 PSI (0.01 MPa)
Repeatability
0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S. *3
Display method
Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator
Connection port
NPT3/4 (20 A)
Other materials
Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC
Rated flow range
0.7 - 13.0 G/min (2.5 - 50 L/min) *1
Detectable fluids
Water or non-corrosive liquid
Relative humidity
35 to 85 % RH (No condensation)
Display resolution
0.1/1 (G/min, L/min) selectable
Ambient temperature
0 to +50 °C 32 to 122 °F (No freezing)
Minimum flow volume
0.7 G/min (2.5 L/min) *5
Pressure resistance
290 PSI (2.0 MPa)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
Accumulated flow unit
0.1/1/10/100/1000 (G, L) selectable
Applied pressure range
Max. 145 PSI (1.0 MPa)
Possible display range
0.7 - 26.4 G/min (2.5 - 100 L/min) *2
Possible ranges to set
0 - 26.4 G/min (0 - 100 L/min)
Rating / Power voltage
24 VDC, Ripple (P-P) 10 % or less, Class 2
Detection fluid temperature
0 to +85°C 32 to 185 °F (No freezing)
Integration data storage cycle
Save to memory every 10 seconds
Material / Liquid end materials
Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)
Conductivity of detection fluids
5 µS/cm or higher
Power consumption (Current consumption)
Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)
Response time (chatter prevention feature)
0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable
Environmental resistance / Enclosure rating
IP65
Control output/Accumulation pulse output/ Error alarm output
PNP open collector, max. 100 mA/ch *4 30 V or less, residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)
Integration reset/bank switch input/flow zero function input
Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode

Compatibility Information

Match FD-MZ50ATKP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FD-MZ50ATKP.

Maintenance Tips

Store FD-MZ50ATKP dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114