KEYENCE FD-H20
Product information
$1,031.87 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: FD-H20
Alternate: FDH20
Brand
KEYENCE
Part No.
FD-H20
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE FD-H20
Product overview
The KEYENCE FD-H20 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Ambient temperature: Sensor head: −20 to +60°C –4 to +140°F (no freezing)
- Analog output (Ch1/2): 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
- Current consumption: 240 mA or less (when using flow sensor standalone
- Data accumulation / Accumulation period: Approx. 1 year
- Data reading: USB2.0
- Detection principle: Delta TOF + Pulse Doppler
- Display: QVGA 2.0 model: color LCD, status indicator light
- Display resolution: Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1)
- Display resolution / Instantaneous flow: 0.01/0.1/1 (L/min) (default value: 0.1)
- Display unit: −20 to +50°C –4 to +122°F (no freezing) *2
- Display update cycle: Approx. 10 times/second
- Environmental resistance / Enclosure rating: IP65/67 (IEC 60529) *9
- External input (Ch2/3): Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input Short circuit current: 1.5 mA or less
- Flow units: L/min m 3 /h G/min
- Function for automatic correction for speed of sound in liquid: Yes
- Heat calculation function / Unit: MJ/h kW kBTU/h *7
- Hysteresis: Variable
- I/O (switchable) / Output (Ch1/2/3/4): Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
- Integrated flow: 0.01/0.1/1 (L) (default value: 0.1
- Integrated value (MJ): 0.01/0.1/1 (default value 0.1) *7
- Maximum rated flow: 1/2" (15A) : 60 L/min 15.9 gal/min 3/4" (20A) : 100 L/min 26.4 gal/min
- Measurement accuracy: Between 10 and 100% of F.S.: ±3.0% of RD *3 *4 Between 0 and 10% of F.S.: ±0.3% of F.S. *3 *4
- Network support: IO-Link *6
- Pipe temperature measurement accuracy: ±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F ) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F ) (ambient temperature of 25°C 77°F ) *3
- Power I/O connector: M12 8-pin connector (male)
- Power supply / Power voltage: 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
- Protection circuit: Protection against reverse power connection, power supply surges, output short circuits, and output surges
- Pulse output increments (L): 0.02–999.99
- Pulse output increments (MJ): 0.02–999.99 *7
- Relative humidity: 35–85% RH (no condensation)
- Repeatability: 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S. *3 *5
- Response time: 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
- Supported fluid temperature: 0–85°C 32–185°F (no freezing on pipe surface) *2
- Supported fluids: All fluids (water, oil, chemicals, etc.) *1
- Supported pipe diameter: 1/2" (15A), ø18–23 ø0.71"-0.91" 3/4" (20A), ø23–28 ø0.91"-1.10"
- Supported pipe materials: Metal piping, hard plastic piping *1
- Type: Standard model
- Vibration resistance: 10–500 Hz
- Zero cut flow rate: 0.5 L/min 0.13 gal/min (variable, initial value)
- input time: 20 ms or more
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number FD-H20 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- FD-H20
- Brand
- KEYENCE
- Part Number
- FD-H20
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Standard model
- Display
- QVGA 2.0 model: color LCD, status indicator light
- Packaging
- New surplus, factory sealed original packaging
- Flow units
- L/min m 3 /h G/min
- Hysteresis
- Variable
- input time
- 20 ms or more
- Data reading
- USB2.0
- Display unit
- −20 to +50°C –4 to +122°F (no freezing) *2
- Repeatability
- 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S. *3 *5
- Response time
- 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
- Integrated flow
- 0.01/0.1/1 (L) (default value: 0.1
- Network support
- IO-Link *6
- Supported fluids
- All fluids (water, oil, chemicals, etc.) *1
- Relative humidity
- 35–85% RH (no condensation)
- Display resolution
- Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1)
- Maximum rated flow
- 1/2" (15A) : 60 L/min 15.9 gal/min 3/4" (20A) : 100 L/min 26.4 gal/min
- Protection circuit
- Protection against reverse power connection, power supply surges, output short circuits, and output surges
- Zero cut flow rate
- 0.5 L/min 0.13 gal/min (variable, initial value)
- Ambient temperature
- Sensor head: −20 to +60°C –4 to +140°F (no freezing)
- Current consumption
- 240 mA or less (when using flow sensor standalone
- Detection principle
- Delta TOF + Pulse Doppler
- Power I/O connector
- M12 8-pin connector (male)
- Display update cycle
- Approx. 10 times/second
- Measurement accuracy
- Between 10 and 100% of F.S.: ±3.0% of RD *3 *4 Between 0 and 10% of F.S.: ±0.3% of F.S. *3 *4
- Vibration resistance
- 10–500 Hz
- Analog output (Ch1/2)
- 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
- Integrated value (MJ)
- 0.01/0.1/1 (default value 0.1) *7
- External input (Ch2/3)
- Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input Short circuit current: 1.5 mA or less
- Supported pipe diameter
- 1/2" (15A), ø18–23 ø0.71"-0.91" 3/4" (20A), ø23–28 ø0.91"-1.10"
- Supported pipe materials
- Metal piping, hard plastic piping *1
- Pulse output increments (L)
- 0.02–999.99
- Supported fluid temperature
- 0–85°C 32–185°F (no freezing on pipe surface) *2
- Power supply / Power voltage
- 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
- Pulse output increments (MJ)
- 0.02–999.99 *7
- Heat calculation function / Unit
- MJ/h kW kBTU/h *7
- I/O (switchable) / Output (Ch1/2/3/4)
- Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
- Pipe temperature measurement accuracy
- ±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F ) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F ) (ambient temperature of 25°C 77°F ) *3
- Data accumulation / Accumulation period
- Approx. 1 year
- Display resolution / Instantaneous flow
- 0.01/0.1/1 (L/min) (default value: 0.1)
- Environmental resistance / Enclosure rating
- IP65/67 (IEC 60529) *9
- Function for automatic correction for speed of sound in liquid
- Yes
Compatibility Information
Match FD-H20 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing FD-H20.
Maintenance Tips
Store FD-H20 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. FD-H20 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
FD-H20 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match FD-H20 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114