KEYENCE FD-H20 Product overview The KEYENCE FD-H20 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient temperature: Sensor head: −20 to +60°C –4 to +140°F (no freezing) - Analog output (Ch1/2): 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less - Current consumption: 240 mA or less (when using flow sensor standalone - Data accumulation / Accumulation period: Approx. 1 year - Data reading: USB2.0 - Detection principle: Delta TOF + Pulse Doppler - Display: QVGA 2.0 model: color LCD, status indicator light - Display resolution: Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1) - Display resolution / Instantaneous flow: 0.01/0.1/1 (L/min) (default value: 0.1) - Display unit: −20 to +50°C –4 to +122°F (no freezing) *2 - Display update cycle: Approx. 10 times/second - Environmental resistance / Enclosure rating: IP65/67 (IEC 60529) *9 - External input (Ch2/3): Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input Short circuit current: 1.5 mA or less - Flow units: L/min m 3 /h G/min - Function for automatic correction for speed of sound in liquid: Yes - Heat calculation function / Unit: MJ/h kW kBTU/h *7 - Hysteresis: Variable - I/O (switchable) / Output (Ch1/2/3/4): Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less - Integrated flow: 0.01/0.1/1 (L) (default value: 0.1 - Integrated value (MJ): 0.01/0.1/1 (default value 0.1) *7 - Maximum rated flow: 1/2" (15A) : 60 L/min 15.9 gal/min 3/4" (20A) : 100 L/min 26.4 gal/min - Measurement accuracy: Between 10 and 100% of F.S.: ±3.0% of RD *3 *4 Between 0 and 10% of F.S.: ±0.3% of F.S. *3 *4 - Network support: IO-Link *6 - Pipe temperature measurement accuracy: ±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F ) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F ) (ambient temperature of 25°C 77°F ) *3 - Power I/O connector: M12 8-pin connector (male) - Power supply / Power voltage: 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS - Protection circuit: Protection against reverse power connection, power supply surges, output short circuits, and output surges - Pulse output increments (L): 0.02–999.99 - Pulse output increments (MJ): 0.02–999.99 *7 - Relative humidity: 35–85% RH (no condensation) - Repeatability: 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S. *3 *5 - Response time: 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s - Supported fluid temperature: 0–85°C 32–185°F (no freezing on pipe surface) *2 - Supported fluids: All fluids (water, oil, chemicals, etc.) *1 - Supported pipe diameter: 1/2" (15A), ø18–23 ø0.71"-0.91" 3/4" (20A), ø23–28 ø0.91"-1.10" - Supported pipe materials: Metal piping, hard plastic piping *1 - Type: Standard model - Vibration resistance: 10–500 Hz - Zero cut flow rate: 0.5 L/min 0.13 gal/min (variable, initial value) - input time: 20 ms or more Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FD-H20 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FD-H20
Brand
KEYENCE
Part Number
FD-H20
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Standard model
Display
QVGA 2.0 model: color LCD, status indicator light
Packaging
New surplus, factory sealed original packaging
Flow units
L/min m 3 /h G/min
Hysteresis
Variable
input time
20 ms or more
Data reading
USB2.0
Display unit
−20 to +50°C –4 to +122°F (no freezing) *2
Repeatability
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S. *3 *5
Response time
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
Integrated flow
0.01/0.1/1 (L) (default value: 0.1
Network support
IO-Link *6
Supported fluids
All fluids (water, oil, chemicals, etc.) *1
Relative humidity
35–85% RH (no condensation)
Display resolution
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1)
Maximum rated flow
1/2" (15A) : 60 L/min 15.9 gal/min 3/4" (20A) : 100 L/min 26.4 gal/min
Protection circuit
Protection against reverse power connection, power supply surges, output short circuits, and output surges
Zero cut flow rate
0.5 L/min 0.13 gal/min (variable, initial value)
Ambient temperature
Sensor head: −20 to +60°C –4 to +140°F (no freezing)
Current consumption
240 mA or less (when using flow sensor standalone
Detection principle
Delta TOF + Pulse Doppler
Power I/O connector
M12 8-pin connector (male)
Display update cycle
Approx. 10 times/second
Measurement accuracy
Between 10 and 100% of F.S.: ±3.0% of RD *3 *4 Between 0 and 10% of F.S.: ±0.3% of F.S. *3 *4
Vibration resistance
10–500 Hz
Analog output (Ch1/2)
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
Integrated value (MJ)
0.01/0.1/1 (default value 0.1) *7
External input (Ch2/3)
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input Short circuit current: 1.5 mA or less
Supported pipe diameter
1/2" (15A), ø18–23 ø0.71"-0.91" 3/4" (20A), ø23–28 ø0.91"-1.10"
Supported pipe materials
Metal piping, hard plastic piping *1
Pulse output increments (L)
0.02–999.99
Supported fluid temperature
0–85°C 32–185°F (no freezing on pipe surface) *2
Power supply / Power voltage
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
Pulse output increments (MJ)
0.02–999.99 *7
Heat calculation function / Unit
MJ/h kW kBTU/h *7
I/O (switchable) / Output (Ch1/2/3/4)
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
Pipe temperature measurement accuracy
±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F ) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F ) (ambient temperature of 25°C 77°F ) *3
Data accumulation / Accumulation period
Approx. 1 year
Display resolution / Instantaneous flow
0.01/0.1/1 (L/min) (default value: 0.1)
Environmental resistance / Enclosure rating
IP65/67 (IEC 60529) *9
Function for automatic correction for speed of sound in liquid
Yes

Compatibility Information

Match FD-H20 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FD-H20.

Maintenance Tips

Store FD-H20 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114