KEYENCE FD-EPA0 Product overview The KEYENCE FD-EPA0 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analog output: Instantaneous flow/Pressure 4-20 mA/0-20 mA (switchable), load resistance: 260 Ω or less - Environmental resistance / Ambient temperature: −10°C to +55°C 14 to 131°F (no freezing) *4 - External inputs 1 and 2: Zero flow/Origin adjust./Atmospheric pressure correction/Pressure zero shift/Reset total/App. learning/App. reset Short-circuit current: 1.5 mA or less - I/O / Control outputs 1, 2, and 3: Instantaneous flow/Accumulated flow/Pressure/Alarm output/Predictive maintenance output/Seating Confirmation (output 1 only)/Pulse output NPN/PNP setting switchable, 100 mA or less total for three outputs, residual voltage: 2.5 V or less - Material: Main unit: polycarbonate, FG terminal: copper/iron - Network compatibility: NU Series compatibility - Number of analog outputs: ─ - Number of connectible units: Eight units per one NU1 main unit - Number of control outputs: ─ *2 - Number of external inputs: ─ *2 - Power consumption: 1400 mW excluding load current *4 - Power supply / Power voltage: 24 VDC ± 10% (including ripple), Class2/LPS - Power supply cable: No cable - Pressure: 2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *3 - Protection circuit: Protection against incorrect head cable wiring - Relative humidity: 35%RH to 85%RH (no condensation) - Response time (90% response) / Flow rate: 50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms) *3 - Shock resistance: 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis - Type: Zero line type *1 - Vibration resistance: 10 to 500 Hz, power spectral concentration: 0.816 G 2 /Hz, XYZ axes - Weight: Approx. 26 g 0.92 oz Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FD-EPA0 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FD-EPA0
Brand
KEYENCE
Part Number
FD-EPA0
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Zero line type *1
Weight
Approx. 26 g 0.92 oz
Material
Main unit: polycarbonate, FG terminal: copper/iron
Pressure
2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *3
Packaging
New surplus, factory sealed original packaging
Analog output
Instantaneous flow/Pressure 4-20 mA/0-20 mA (switchable), load resistance: 260 Ω or less
Shock resistance
100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
Power consumption
1400 mW excluding load current *4
Relative humidity
35%RH to 85%RH (no condensation)
Power supply cable
No cable
Protection circuit
Protection against incorrect head cable wiring
Vibration resistance
10 to 500 Hz, power spectral concentration: 0.816 G 2 /Hz, XYZ axes
Network compatibility
NU Series compatibility
External inputs 1 and 2
Zero flow/Origin adjust./Atmospheric pressure correction/Pressure zero shift/Reset total/App. learning/App. reset Short-circuit current: 1.5 mA or less
Number of analog outputs
─
Number of control outputs
─ *2
Number of external inputs
─ *2
Number of connectible units
Eight units per one NU1 main unit
Power supply / Power voltage
24 VDC ± 10% (including ripple), Class2/LPS
I/O / Control outputs 1, 2, and 3
Instantaneous flow/Accumulated flow/Pressure/Alarm output/Predictive maintenance output/Seating Confirmation (output 1 only)/Pulse output NPN/PNP setting switchable, 100 mA or less total for three outputs, residual voltage: 2.5 V or less
Response time (90% response) / Flow rate
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms) *3
Environmental resistance / Ambient temperature
−10°C to +55°C 14 to 131°F (no freezing) *4

Compatibility Information

Match FD-EPA0 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FD-EPA0.

Maintenance Tips

Store FD-EPA0 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114