KEYENCE FD-ECH7
Product information
$700.94 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: FD-ECH7
Alternate: FDECH7
Brand
KEYENCE
Part No.
FD-ECH7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE FD-ECH7
Product overview
The KEYENCE FD-ECH7 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- (20°C 68°F , atmospheric pressure conversion) / Gas at 20°C 68°F , 0.2 MPa: 120 L/min 4.24 CFM
- Accumulated flow: 0.01/0.1/1/10/100 L
- Ambient temperature: −10°C to +60°C 14 to 140°F (no freezing)
- Display method: Output indicator
- Display resolution / Instantaneous flow: 0.01/0.1/1 L/min
- Environmental resistance / Enclosure rating: IP65 (IEC60529)
- Flow rate detection principle: Ultrasonic transmission time difference method
- Gas at 20°C 68°F , 0.4 MPa: 200 L/min 7.06 CFM
- Gas at 20°C 68°F , 0.6 MPa: 280 L/min 9.88 CFM
- Installable range: 6.35 0.25" ± 0.15 mm 0.01"
- Material / Sensor unit: PBT/PAR/iron
- Operating pressure range: 0 to 0.75 MPa (upper limit depends on pipe specifications)
- Pipe materials: Polyurethane, nylon, PFA, *1 other *2
- Pipe size / Outer diameter of pipe: 1/4" (approx. 6.35 mm 0.25" )
- Rated flow rate / (volume flow rate): 40 L/min 1.41 CFM * Initial display
- Relative humidity: 35%RH to 85%RH (no condensation)
- Repeatability: Response time 250 ms: ±2.5% of F.S. *4 *5
- Sensor surface: Special rubber
- Shock resistance: 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
- Supported gas temperature: −10°C to +60°C 14 to 140°F
- Supported gases: Air, nitrogen, argon, and other gases *3
- Vibration resistance: 10 to 500 Hz, power spectral concentration: 0.816 G 2 /Hz, XYZ axes
- Weight: Approx. 102 g 3.60 oz
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number FD-ECH7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- FD-ECH7
- Brand
- KEYENCE
- Part Number
- FD-ECH7
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Weight
- Approx. 102 g 3.60 oz
- Packaging
- New surplus, never used
- Repeatability
- Response time 250 ms: ±2.5% of F.S. *4 *5
- Display method
- Output indicator
- Pipe materials
- Polyurethane, nylon, PFA, *1 other *2
- Sensor surface
- Special rubber
- Supported gases
- Air, nitrogen, argon, and other gases *3
- Accumulated flow
- 0.01/0.1/1/10/100 L
- Shock resistance
- 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
- Installable range
- 6.35 0.25" ± 0.15 mm 0.01"
- Relative humidity
- 35%RH to 85%RH (no condensation)
- Ambient temperature
- −10°C to +60°C 14 to 140°F (no freezing)
- Vibration resistance
- 10 to 500 Hz, power spectral concentration: 0.816 G 2 /Hz, XYZ axes
- Material / Sensor unit
- PBT/PAR/iron
- Operating pressure range
- 0 to 0.75 MPa (upper limit depends on pipe specifications)
- Supported gas temperature
- −10°C to +60°C 14 to 140°F
- Gas at 20°C 68°F , 0.4 MPa
- 200 L/min 7.06 CFM
- Gas at 20°C 68°F , 0.6 MPa
- 280 L/min 9.88 CFM
- Flow rate detection principle
- Ultrasonic transmission time difference method
- Pipe size / Outer diameter of pipe
- 1/4" (approx. 6.35 mm 0.25" )
- Rated flow rate / (volume flow rate)
- 40 L/min 1.41 CFM * Initial display
- Display resolution / Instantaneous flow
- 0.01/0.1/1 L/min
- Environmental resistance / Enclosure rating
- IP65 (IEC60529)
- (20°C 68°F , atmospheric pressure conversion) / Gas at 20°C 68°F , 0.2 MPa
- 120 L/min 4.24 CFM
Compatibility Information
Match FD-ECH7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing FD-ECH7.
Maintenance Tips
Store FD-ECH7 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. FD-ECH7 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
FD-ECH7 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match FD-ECH7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114