KEYENCE EX-V01E
Product information
$1,311.92 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: EX-V01E
Alternate: EXV01E
Brand
KEYENCE
Part No.
EX-V01E
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE EX-V01E
Product overview
The KEYENCE EX-V01E is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Alarm output: NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.)
- Analog output voltage / Output voltage: ±5V
- Control input / Timing input: NPN open-collector or non-voltage contact signal
- Control output / Setting method: Upper/lower 2-level setting x 4 patterns (selectable)
- Current consumption: 240 mA or less
- Display power: 7-segment 2-color LED
- Display range: -19,999 to +19,999
- Display speed: 20 times/sec. (2-color, 7-segment LED)
- Environmental resistance / Ambient temperature: 0 to +50 °C 32 to 122 °F
- Impedance: 100 Ω
- Linearity: ±0.3% of F.S.
- Major functions: FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.
- Measuring range: 0 to 1 mm 0.04"
- OFF-delay time: 60 ms (ON/OFF selectable)
- Over-range alarm: ±FFFF is displayed.
- Rating / Power voltage: 24 VDC ±10 %, Ripple (P-P) 10 % or less
- Relative humidity: 35 to 85 % RH (No condensation)
- Resolution (No. of averaging measurements: 64): 0.4 µm 0.016 Mil
- Response time: 0.075 ms (at maximum speed)
- Sampling rate: 40,000 samplings max./sec. *1
- Shape: ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical
- Signal: NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)
- Strobe output: NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.)
- Temperature characteristics: 0.07% of F.S./°C *2
- Type: Controller
- Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Weight: Approx. 235 g
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number EX-V01E with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- EX-V01E
- Brand
- KEYENCE
- Part Number
- EX-V01E
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Controller
- Shape
- ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical
- Signal
- NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)
- Weight
- Approx. 235 g
- Impedance
- 100 Ω
- Linearity
- ±0.3% of F.S.
- Packaging
- New surplus, never used
- Alarm output
- NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.)
- Display power
- 7-segment 2-color LED
- Display range
- -19,999 to +19,999
- Display speed
- 20 times/sec. (2-color, 7-segment LED)
- Response time
- 0.075 ms (at maximum speed)
- Sampling rate
- 40,000 samplings max./sec. *1
- Strobe output
- NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.)
- OFF-delay time
- 60 ms (ON/OFF selectable)
- Major functions
- FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.
- Measuring range
- 0 to 1 mm 0.04"
- Over-range alarm
- ±FFFF is displayed.
- Relative humidity
- 35 to 85 % RH (No condensation)
- Current consumption
- 240 mA or less
- Vibration resistance
- 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Rating / Power voltage
- 24 VDC ±10 %, Ripple (P-P) 10 % or less
- Temperature characteristics
- 0.07% of F.S./°C *2
- Control input / Timing input
- NPN open-collector or non-voltage contact signal
- Control output / Setting method
- Upper/lower 2-level setting x 4 patterns (selectable)
- Analog output voltage / Output voltage
- ±5V
- Resolution (No. of averaging measurements
- 64): 0.4 µm 0.016 Mil
- Environmental resistance / Ambient temperature
- 0 to +50 °C 32 to 122 °F
Compatibility Information
Match EX-V01E against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing EX-V01E.
Maintenance Tips
Store EX-V01E dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. EX-V01E is in stock and ships within 1-2 business days, with a tracking number for every shipment.
EX-V01E is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match EX-V01E against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114