Product Description

Schneider Electric CA2KN22Z7 Product overview The Schneider Electric CA2KN22Z7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660 - Characteristic: Value(s) - Connections - terminals: screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible with cable end screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible without cable end - Contactor application: Control circuit - Control circuit type: AC 50/60 Hz - Control circuit voltage limits: Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) - Depth: 2.2 in (57 mm) - Device short name: CA2K - Heat dissipation: 1.3 W - Height: 2.3 in (58 mm) - Hold-in power consumption in VA: 4.5 VA (at 68 °F (20 °C)) - Immunity to microbreaks: 2 ms - Inrush power in VA: 30 VA (at 68 °F (20 °C)) - Insulation resistance: > 10 MOhm - Irms rated making capacity: 110 A IEC 60947 - Maximum operating rate: 10000 cyc/h - Mechanical durability: 10 Mcycles - Minimum switching current: 5 mA - Minimum switching voltage: 17 V - Mounting Support: Rail Plate - Non overlap distance: 0.02 in (0.5 mm) - Operating time: 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening - Pole contact composition: 2 NO + 2 NC - Product Weight: 0.40 lb(US) (0.18 kg) - Product or Component Type: Control relay - Range: TeSys - Tightening torque: 11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm 11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.2 in (6 mm) - Utilisation category: DC-13 AC-15 - Width: 1.8 in (45 mm) - [Ith] conventional free air thermal current: 10 A (at 122 °F (50 °C)) - [Uc] control circuit voltage: 20 V AC 50/60 Hz - [Ue] rated operational voltage: <= 690 V <= 400 Hz - [Ui] rated insulation voltage: 690 V IEC 60947 750 V VDE 0110 group C 690 V BS 5424 600 V CSA C22.2 No 14 - product name: TeSys CAK Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number CA2KN22Z7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
CA2KN22Z7
Brand
Schneider Electric
Part Number
CA2KN22Z7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
2.2 in (57 mm)
Range
TeSys
Width
1.8 in (45 mm)
Height
2.3 in (58 mm)
product name
TeSys CAK
Characteristic
Value(s)
Operating time
10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening
Product Weight
0.40 lb(US) (0.18 kg)
Heat dissipation
1.3 W
Mounting Support
Rail Plate
Device short name
CA2K
Tightening torque
11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm 11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.2 in (6 mm)
Inrush power in VA
30 VA (at 68 °F (20 °C))
Control circuit type
AC 50/60 Hz
Non overlap distance
0.02 in (0.5 mm)
Utilisation category
DC-13 AC-15
Contactor application
Control circuit
Insulation resistance
> 10 MOhm
Mechanical durability
10 Mcycles
Associated fuse rating
10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660
Maximum operating rate
10000 cyc/h
Connections - terminals
screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible with cable end screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible without cable end
Immunity to microbreaks
2 ms
Pole contact composition
2 NO + 2 NC
Minimum switching current
5 mA
Minimum switching voltage
17 V
Product or Component Type
Control relay
Irms rated making capacity
110 A IEC 60947
[Uc] control circuit voltage
20 V AC 50/60 Hz
[Ui] rated insulation voltage
690 V IEC 60947 750 V VDE 0110 group C 690 V BS 5424 600 V CSA C22.2 No 14
Control circuit voltage limits
Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) Operational: 0.8...1.15 Uc (at <122 °F (50 °C))
[Ue] rated operational voltage
<= 690 V <= 400 Hz
Hold-in power consumption in VA
4.5 VA (at 68 °F (20 °C))
[Ith] conventional free air thermal current
10 A (at 122 °F (50 °C))

Compatibility Information

Match CA2KN22Z7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing CA2KN22Z7.

Maintenance Tips

Store CA2KN22Z7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options