+86 13348028050
C63F31M500 Schneider Electric C63F31M500 - Front View | Vcocnc FANUC Parts

Schneider Electric C63F31M500

Product information

$617.51 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: C63F31M500

Alternate: C63F31M500

Brand
Schneider Electric
Part No.
C63F31M500
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric C63F31M500 Product overview The Schneider Electric C63F31M500 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 45 mm - Device application: Motor protection - Device short name: NSX630F - Downside connection: Front - Earth-leakage protection: Without - Electrical durability: 8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In - Instantaneous protection pick-up adjustment type Ii: Fixed - Mechanical durability: 15000 cycles - Mounting position: Horizontal and vertical Flat on the back - Mounting support: Backplate - Network frequency: 50/60 Hz - Network type: AC - Performance level: F 36 kA 415 V AC - Poles description: 3P - Power dissipation per pole: 25 W - Product or component type: Circuit breaker - Protected poles description: 3D - Protection type: S : for short time short-circuit protection I : for instantaneous short-circuit protection - Range: ComPacT - Short-time protection delay adjustment type tsd: Fixed - Short-time protection pick-up adjustment type Isd: Adjustable 9 settings - Suitability for isolation: Yes conforming to EN/IEC 60947-2 - Trip unit name: MicroLogic 1.3 M - Trip unit protection functions: SI - Trip unit rating: 500 A at 65 °C - Trip unit technology: Electronic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 - [Ii] instantaneous protection pick-up adjustment range: 6500 A - [In] rated current: 500 A at 65 °C - [Isd] Short-time protection pick-up adjustment range: 2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 5500 A 6000 A 6500 A - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - control type: Toggle - product name: ComPacT NSX Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number C63F31M500 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
C63F31M500
Brand
Schneider Electric
Part Number
C63F31M500
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPacT
Packaging
New surplus, factory sealed original packaging
Network type
AC
control type
Toggle
product name
ComPacT NSX
Characteristic
Value(s)
Trip unit name
MicroLogic 1.3 M
Protection type
S : for short time short-circuit protection I : for instantaneous short-circuit protection
Connection pitch
45 mm
Mounting support
Backplate
Trip unit rating
500 A at 65 °C
Device short name
NSX630F
Mounting position
Horizontal and vertical Flat on the back
Network frequency
50/60 Hz
Performance level
F 36 kA 415 V AC
Poles description
3P
Upside connection
Front
Device application
Motor protection
[In] rated current
500 A at 65 °C
Downside connection
Front
Trip unit technology
Electronic
Utilisation category
Category A
Electrical durability
8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability
15000 cycles
Earth-leakage protection
Without
Product or component type
Circuit breaker
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Power dissipation per pole
25 W
Protected poles description
3D
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Trip unit protection functions
SI
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Short-time protection delay adjustment type tsd
Fixed
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
Instantaneous protection pick-up adjustment type Ii
Fixed
[Ics] rated service short-circuit breaking capacity
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
[Isd] Short-time protection pick-up adjustment range
2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 5500 A 6000 A 6500 A
[Ii] instantaneous protection pick-up adjustment range
6500 A

Compatibility Information

Match C63F31M500 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing C63F31M500.

Maintenance Tips

Store C63F31M500 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options