Schneider Electric C25F34V250 Product overview The Schneider Electric C25F34V250 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 35 mm - Device application: Distribution - Device short name: NSX250F - Downside connection: Front - Electrical durability: 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In - Long-time pick-up adjustment type Ir (thermal protection): Adjustable 9 settings - Long-time protection delay adjustment type tr: Fixed - Mechanical durability: 20000 cycles - Mounting position: Horizontal and vertical Flat on the back - Mounting support: Backplate - Network frequency: 50/60 Hz - Network type: AC - Performance level: F 36 kA 415 V AC - Poles description: 3P - Power dissipation per pole: 25 W N 25 W L1 and L3 20.6 W L2 - Product or component type: Earth leakage circuit breaker - Protected poles description: 3D - Protection type: L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection R : for earth-leakage protection - Range: ComPacT - Short-time protection pick-up adjustment type Isd: Adjustable - Suitability for isolation: Yes conforming to EN/IEC 60947-2 - Thermal memory: 20 minutes before and after tripping - Trip unit name: MicroLogic 4.2 - Trip unit protection functions: LSoIR - Trip unit rating: 250 A at 40 °C - Trip unit technology: Electronic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 - [In] rated current: 250 A at 40 °C - [Ir] long-time protection pick-up adjustment range: 100...250 A - [Ue] rated operational voltage: 440 V AC 50/60 Hz - [Ui] rated insulation voltage: 500 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - [tr] long-time protection delay adjustment range: 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir - control type: Toggle - product name: ComPacT NSX Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number C25F34V250 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
C25F34V250
Brand
Schneider Electric
Part Number
C25F34V250
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPacT
Packaging
New surplus, factory sealed original packaging
Network type
AC
control type
Toggle
product name
ComPacT NSX
Characteristic
Value(s)
Thermal memory
20 minutes before and after tripping
Trip unit name
MicroLogic 4.2
Protection type
L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection R : for earth-leakage protection
Connection pitch
35 mm
Mounting support
Backplate
Trip unit rating
250 A at 40 °C
Device short name
NSX250F
Mounting position
Horizontal and vertical Flat on the back
Network frequency
50/60 Hz
Performance level
F 36 kA 415 V AC
Poles description
3P
Upside connection
Front
Device application
Distribution
[In] rated current
250 A at 40 °C
Downside connection
Front
Trip unit technology
Electronic
Utilisation category
Category A
Electrical durability
20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability
20000 cycles
Product or component type
Earth leakage circuit breaker
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Power dissipation per pole
25 W N 25 W L1 and L3 20.6 W L2
Protected poles description
3D
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
500 V AC 50/60 Hz
Trip unit protection functions
LSoIR
[Ue] rated operational voltage
440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Long-time protection delay adjustment type tr
Fixed
[tr] long-time protection delay adjustment range
400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir
Short-time protection pick-up adjustment type Isd
Adjustable
[Ir] long-time protection pick-up adjustment range
100...250 A
[Ics] rated service short-circuit breaking capacity
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings

Compatibility Information

Match C25F34V250 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing C25F34V250.

Maintenance Tips

Store C25F34V250 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options