Product Description

Schneider Electric C10N3MA025 Product overview The Schneider Electric C10N3MA025 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Circuit breaker mounting mode: Fixed - Connection pitch: 35 mm - Device application: Motor protection - Device short name: NSX100N - Downside connection: Front - Earth-leakage protection: Without - Electrical durability: 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In - Instantaneous protection pick-up adjustment type Ii: Adjustable 9 settings - Mechanical durability: 50000 cycles - Mounting position: Horizontal and vertical Flat on the back - Mounting support: Backplate - Network frequency: 50/60 Hz - Network type: AC - Number of slots for electrical auxiliaries: 5 slot(s) - Performance level: N 50 kA 415 V AC - Poles description: 3P - Power dissipation per pole: 1.04 W - Product or component type: Circuit breaker - Protected poles description: 3D - Protection type: I : for short-circuit protection (magnetic) - Range: ComPacT - Short-time protection pick-up adjustment type Isd: Adjustable 9 settings - Suitability for isolation: Yes conforming to EN/IEC 60947-2 - Trip unit name: MA - Trip unit protection functions: I - Trip unit rating: 25 A at 65 °C - Trip unit technology: Magnetic - Upside connection: Front - Utilisation category: Category A - [Ics] rated service short-circuit breaking capacity: 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 - [Icu] rated ultimate short-circuit breaking capacity: 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 - [Ii] instantaneous protection pick-up adjustment range: 6...14 x In - [In] rated current: 25 A at 65 °C - [Isd] Short-time protection pick-up adjustment range: 6...14 x In - [Ue] rated operational voltage: 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 800 V AC 50/60 Hz - [Uimp] rated impulse withstand voltage: 8 kV - control type: Toggle - product name: ComPacT NSX Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number C10N3MA025 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
C10N3MA025
Brand
Schneider Electric
Part Number
C10N3MA025
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
ComPacT
Packaging
New surplus, factory sealed original packaging
Network type
AC
control type
Toggle
product name
ComPacT NSX
Characteristic
Value(s)
Trip unit name
MA
Protection type
I : for short-circuit protection (magnetic)
Connection pitch
35 mm
Mounting support
Backplate
Trip unit rating
25 A at 65 °C
Device short name
NSX100N
Mounting position
Horizontal and vertical Flat on the back
Network frequency
50/60 Hz
Performance level
N 50 kA 415 V AC
Poles description
3P
Upside connection
Front
Device application
Motor protection
[In] rated current
25 A at 65 °C
Downside connection
Front
Trip unit technology
Magnetic
Utilisation category
Category A
Electrical durability
50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability
50000 cycles
Earth-leakage protection
Without
Product or component type
Circuit breaker
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Power dissipation per pole
1.04 W
Protected poles description
3D
Circuit breaker mounting mode
Fixed
[Ui] rated insulation voltage
800 V AC 50/60 Hz
Trip unit protection functions
I
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Number of slots for electrical auxiliaries
5 slot(s)
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
Instantaneous protection pick-up adjustment type Ii
Adjustable 9 settings
[Ics] rated service short-circuit breaking capacity
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icu] rated ultimate short-circuit breaking capacity
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
[Isd] Short-time protection pick-up adjustment range
6...14 x In
[Ii] instantaneous protection pick-up adjustment range
6...14 x In

Compatibility Information

Match C10N3MA025 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing C10N3MA025.

Maintenance Tips

Store C10N3MA025 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options