Product Description

Schneider Electric BMXDRA0805H Product overview The Schneider Electric BMXDRA0805H is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Characteristic: Value(s) - Discrete output number: 8 EN/IEC 61131-2 - Discrete output type: Relay - Discrete output voltage: 24...240 V 19...264 V AC 12...24 V 10...34 V DC - Electrical durability: AC-15 100000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-15 100000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 1000000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-12 1000000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 30 VA 48 V 158 °F (70 °C) AC-12 1000000 cycles 50 VA 48 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 66 VA 110...120 V 158 °F (70 °C) AC-15 1000000 cycles 110 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 1000000 cycles 66 VA 200...240 V 158 °F (70 °C) DC-12 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-12 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) DC-13 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-13 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) AC-15 10000000 cycles 10 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 10 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 6 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 10000000 cycles 6 VA 200...240 V 158 °F (70 °C) AC-15 150000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 150000 cycles 66 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 30 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 50 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 2000000 cycles 14.4 VA 48 V 158 °F (70 °C) 0.35) AC-15 2000000 cycles 24 VA 48 V -13…140 °F (-25…60 °C) 0.35) DC-13 2000000 cycles 10 W 24 V -13…140 °F (-25…60 °C) DC-13 2000000 cycles 6 W 24 V 158 °F (70 °C) DC-12 300000 cycles 24 W 24 V 158 °F (70 °C) DC-12 300000 cycles 40 W 24 V -13…140 °F (-25…60 °C) AC-15 3000000 cycles 30 VA 200...240 V 158 °F (70 °C) AC-15 3000000 cycles 50 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 500000 cycles 110 VA 48 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 132 VA 110...120 V 158 °F (70 °C) AC-12 500000 cycles 220 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 66 VA 48 V 158 °F (70 °C) AC-15 5000000 cycles 10 VA 48 V -13…140 °F (-25…60 °C) 0.35) AC-15 500000 cycles 14.4 VA 24 V 158 °F (70 °C) 0.35) AC-15 500000 cycles 24 VA 24 V -13…140 °F (-25…60 °C) 0.35) AC-15 5000000 cycles 6 VA 48 V 158 °F (70 °C) 0.35) AC-12 700000 cycles 30 VA 24 V 158 °F (70 °C) AC-12 700000 cycles 50 VA 24 V -13…140 °F (-25…60 °C) - Insulation resistance: > 10 MOhm 500 V DC - MTBF reliability: 2119902 H - Minimum switching current: 10 mA 5 V DC - Output overload protection: Use 1 fast blow fuse per channel or group of channel - Output overvoltage protection: Use discharge diode on each output DC Use RC circuit on each output AC Use ZNO surge limiter on each output AC - Output short-circuit protection: Use 1 fast blow fuse per channel or group of channel - Power dissipation in W: 2.7 W - Product Specific Application: For severe environments - Product Weight: 0.320 lb(US) (0.145 kg) - Product or Component Type: Discrete output module - Range of Product: Modicon X80 - Response time on output: < 10 ms activation < 8 ms deactivation - Status LED: 1 LED (Green) module operating (RUN) 1 LED per channel (Green) channel diagnostic 1 LED (Red) module error (ERR) 1 LED (Red) module I/O - Typical current consumption: 79 mA 3.3 V DC - [Ith] conventional free air thermal current: 3 A Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number BMXDRA0805H with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
BMXDRA0805H
Brand
Schneider Electric
Part Number
BMXDRA0805H
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Packaging
New surplus, never used
Status LED
1 LED (Green) module operating (RUN) 1 LED per channel (Green) channel diagnostic 1 LED (Red) module error (ERR) 1 LED (Red) module I/O
Characteristic
Value(s)
Product Weight
0.320 lb(US) (0.145 kg)
MTBF reliability
2119902 H
Range of Product
Modicon X80
Discrete output type
Relay
Electrical durability
AC-15 100000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-15 100000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 1000000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 132 VA 200...240 V 158 °F (70 °C) AC-12 1000000 cycles 220 VA 200...240 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 30 VA 48 V 158 °F (70 °C) AC-12 1000000 cycles 50 VA 48 V -13…140 °F (-25…60 °C) AC-12 1000000 cycles 66 VA 110...120 V 158 °F (70 °C) AC-15 1000000 cycles 110 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 1000000 cycles 66 VA 200...240 V 158 °F (70 °C) DC-12 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-12 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) DC-13 1000000 cycles 14.4 W 24 V 158 °F (70 °C) DC-13 1000000 cycles 24 W 24 V -13…140 °F (-25…60 °C) AC-15 10000000 cycles 10 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 10 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-15 10000000 cycles 6 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 10000000 cycles 6 VA 200...240 V 158 °F (70 °C) AC-15 150000 cycles 110 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 150000 cycles 66 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 30 VA 110...120 V 158 °F (70 °C) 0.35) AC-15 1500000 cycles 50 VA 110...120 V -13…140 °F (-25…60 °C) 0.35) AC-15 2000000 cycles 14.4 VA 48 V 158 °F (70 °C) 0.35) AC-15 2000000 cycles 24 VA 48 V -13…140 °F (-25…60 °C) 0.35) DC-13 2000000 cycles 10 W 24 V -13…140 °F (-25…60 °C) DC-13 2000000 cycles 6 W 24 V 158 °F (70 °C) DC-12 300000 cycles 24 W 24 V 158 °F (70 °C) DC-12 300000 cycles 40 W 24 V -13…140 °F (-25…60 °C) AC-15 3000000 cycles 30 VA 200...240 V 158 °F (70 °C) AC-15 3000000 cycles 50 VA 200...240 V -13…140 °F (-25…60 °C) 0.35) AC-12 500000 cycles 110 VA 48 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 132 VA 110...120 V 158 °F (70 °C) AC-12 500000 cycles 220 VA 110...120 V -13…140 °F (-25…60 °C) AC-12 500000 cycles 66 VA 48 V 158 °F (70 °C) AC-15 5000000 cycles 10 VA 48 V -13…140 °F (-25…60 °C) 0.35) AC-15 500000 cycles 14.4 VA 24 V 158 °F (70 °C) 0.35) AC-15 500000 cycles 24 VA 24 V -13…140 °F (-25…60 °C) 0.35) AC-15 5000000 cycles 6 VA 48 V 158 °F (70 °C) 0.35) AC-12 700000 cycles 30 VA 24 V 158 °F (70 °C) AC-12 700000 cycles 50 VA 24 V -13…140 °F (-25…60 °C)
Insulation resistance
> 10 MOhm 500 V DC
Discrete output number
8 EN/IEC 61131-2
Power dissipation in W
2.7 W
Discrete output voltage
24...240 V 19...264 V AC 12...24 V 10...34 V DC
Response time on output
< 10 ms activation < 8 ms deactivation
Minimum switching current
10 mA 5 V DC
Product or Component Type
Discrete output module
Output overload protection
Use 1 fast blow fuse per channel or group of channel
Typical current consumption
79 mA 3.3 V DC
Product Specific Application
For severe environments
Output overvoltage protection
Use discharge diode on each output DC Use RC circuit on each output AC Use ZNO surge limiter on each output AC
Output short-circuit protection
Use 1 fast blow fuse per channel or group of channel
[Ith] conventional free air thermal current
3 A

Compatibility Information

Match BMXDRA0805H against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing BMXDRA0805H.

Maintenance Tips

Store BMXDRA0805H dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options