+86 13348028050
BDL16100 Schneider Electric BDL16100 - Front View | Vcocnc FANUC Parts

Schneider Electric BDL16100

Product information

SKU: BDL16100

Alternate: BDL16100

Brand
Schneider Electric
Part No.
BDL16100
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric BDL16100 Product overview The Schneider Electric BDL16100 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 9 mm pitches: 3 - AWG gauge: AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper - Breaking capacity: 25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480Y/277 V AC 50/60 Hz UL 489 10 kA 125 V DC 50/60 Hz UL 489 14 kA 600/347 V AC 50/60 Hz UL 489 - Breaking capacity code: D - Characteristic: Value(s) - Circuit breaker application: HACR rated - Color: Gray RAL 7016) - Connection pitch: 1.06 in (27 mm) - Continuous current rating: 80 % - Control Type: Toggle - Depth: 3.1 in (80 mm) - Device Application: Distribution - Device short name: BD 100 - Electrical connection: Everlink lug, line Everlink lug, load - Electrical durability: 10000 cycles IEC 947-1 Annex K ed 5.2 In - Height: 5.4 in (137 mm) - Line Rated Current: 100 A - Mechanical durability: 15000 cycles IEC 947-1 Annex F ed 5.2 - Mounting mode: Clip-on 35 mm symmetrical DIN rail) By screws plate) - Network Frequency: 50/60 Hz - Number of Poles: 1P - Power wire stripping length: 0.8 in (20 mm) - Product Weight: 1.12 lb(US) (0.51 kg) - Product or Component Type: Circuit breaker - Protected poles description: 1t - Quantity per Set: Set of 1 - Range: PowerPact - Suitability for isolation: Yes IEC 60947-2 - Tightening torque: 44.3 lbf.in (5 N.m) 0.004…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.7 lbf.in (9 N.m) 0.04…0.1 in² (25…95 mm²) (AWG 3...AWG 3/0) - Trip unit name: TM-D - Trip unit technology: Thermal-magneticTM-D, - Utilisation category: Category A - Width: 1.06 in (27 mm) - [Ics] rated service breaking capacity: 25 kA 220...240 V AC 50/60 Hz IEC 60947-2 - [Ue] rated operational voltage: 240 V AC 50/60 Hz UL 489 - [Ui] rated insulation voltage: 800 V IEC 60947-2 - [Uimp] rated impulse withstand voltage: 8 kV IEC 60947-2 - product name: PowerPact B Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number BDL16100 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
BDL16100
Brand
Schneider Electric
Part Number
BDL16100
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Color
Gray RAL 7016)
Depth
3.1 in (80 mm)
Range
PowerPact
Width
1.06 in (27 mm)
Height
5.4 in (137 mm)
AWG gauge
AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
9 mm pitches
3
Control Type
Toggle
product name
PowerPact B
Mounting mode
Clip-on 35 mm symmetrical DIN rail) By screws plate)
Characteristic
Value(s)
Product Weight
1.12 lb(US) (0.51 kg)
Trip unit name
TM-D
Number of Poles
1P
Connection pitch
1.06 in (27 mm)
Quantity per Set
Set of 1
Breaking capacity
25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480Y/277 V AC 50/60 Hz UL 489 10 kA 125 V DC 50/60 Hz UL 489 14 kA 600/347 V AC 50/60 Hz UL 489
Device short name
BD 100
Network Frequency
50/60 Hz
Tightening torque
44.3 lbf.in (5 N.m) 0.004…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.7 lbf.in (9 N.m) 0.04…0.1 in² (25…95 mm²) (AWG 3...AWG 3/0)
Device Application
Distribution
Line Rated Current
100 A
Trip unit technology
Thermal-magneticTM-D,
Utilisation category
Category A
Electrical connection
Everlink lug, line Everlink lug, load
Electrical durability
10000 cycles IEC 947-1 Annex K ed 5.2 In
Mechanical durability
15000 cycles IEC 947-1 Annex F ed 5.2
Breaking capacity code
D
Continuous current rating
80 %
Product or Component Type
Circuit breaker
Suitability for isolation
Yes IEC 60947-2
Circuit breaker application
HACR rated
Power wire stripping length
0.8 in (20 mm)
Protected poles description
1t
[Ui] rated insulation voltage
800 V IEC 60947-2
[Ue] rated operational voltage
240 V AC 50/60 Hz UL 489
[Ics] rated service breaking capacity
25 kA 220...240 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV IEC 60947-2

Compatibility Information

Match BDL16100 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing BDL16100.

Maintenance Tips

Store BDL16100 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options