+86 13348028050
ATV71LD27M3Z Schneider Electric ATV71LD27M3Z - Front View | Vcocnc FANUC Parts

Schneider Electric ATV71LD27M3Z

Product information

SKU: ATV71LD27M3Z

Alternate: ATV71LD27M3Z

Brand
Schneider Electric
Part No.
ATV71LD27M3Z
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric ATV71LD27M3Z Product overview The Schneider Electric ATV71LD27M3Z is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Accuracy: +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C +/- 0.6 % (AI2) for a temperature variation 60 °C +/- 1 % (AO1) for a temperature variation 60 °C - Analogue output type: AO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V 20 A - Apparent power: 12.8 kVA at 240 V 3 phases 5.5 kW / 7.5 hp - Braking torque: 30 % without braking resistor <= 150 % with braking or hoist resistor - Characteristic: Value(s) - Communication port protocol: CANopen Modbus - Device short name: ATV71 - Discrete output type: Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles Configurable relay logic: (R2A, R2B) NO - 100000 cycles - Electrical connection: Terminal, clamping capacity: 2.5 mm², AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) Terminal, clamping capacity: 6 mm², AWG 8 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) - Insulation: Electrical between power and control - Line current: 35 A for 200 V 3 phases 5.5 kW / 7.5 hp 30.8 A for 240 V 3 phases 5.5 kW / 7.5 hp - Linearity error: +/- 0.15 % of maximum value (AI1-/Al1+, AI2) +/- 0.2 % (AO1) - Local signalling: 1 LED (red) for drive voltage - Maximum switching current: 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2) 2 A at 250 V AC on inductive load - cos phi = 0.4 - - Maximum transient current: 37.4 A for 2 s 3 phases / 5.5 kW / 7.5 hp - Minimum switching current: 3 mA at 24 V DC for configurable relay logic - Motor power hp: 7.5 hp, 3 phases at 200...240 V - Motor power kW: 5.5 kW, 3 phases at 200...240 V - Network number of phases: 3 phases - Nominal output current: 27.5 A at 4 kHz 230 V 3 phases 5.5 kW / 7.5 hp - Output voltage: <= power supply voltage - Product destination: Synchronous motors Asynchronous motors - Product or component type: Variable speed drive - Product specific application: Lift - Prospective line Isc: 22 kA for 3 phases - Range of product: Altivar Lift - Response time: R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s) R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s) AO1 2 ms, tolerance +/- 0.5 ms for analog output(s) <= 100 ms in STO (Safe Torque Off) - Sampling duration: 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s) 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s) 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s) 2 ms +/- 0.5 ms (Al2) - analog input(s) - Speed drive output frequency: 0…599 Hz - Speed range: 1…100 for asynchronous motor in open-loop mode, without speed feedback 1…50 for synchronous motor in open-loop mode, without speed feedback 1…1000 for asynchronous motor in closed-loop mode with encoder feedback - Supply: Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection - Supply frequency: 50...60 Hz - 5...5 % - Supply voltage limits: 170…264 V - Tightening torque: 3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) - Torque accuracy: +/- 5 % in closed-loop mode with encoder feedback +/- 15 % in open-loop mode, without speed feedback - Transient overtorque: 170 %, +/- 10 % for 60 s 220 %, +/- 10 % for 2 s - Variant: With integrated 7-segment display terminal - [Us] rated supply voltage: 200...240 V - 15...10 % - type of cable for external connection: Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number ATV71LD27M3Z with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
ATV71LD27M3Z
Brand
Schneider Electric
Part Number
ATV71LD27M3Z
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Supply
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Variant
With integrated 7-segment display terminal
Accuracy
+/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C +/- 0.6 % (AI2) for a temperature variation 60 °C +/- 1 % (AO1) for a temperature variation 60 °C
Insulation
Electrical between power and control
Speed range
1…100 for asynchronous motor in open-loop mode, without speed feedback 1…50 for synchronous motor in open-loop mode, without speed feedback 1…1000 for asynchronous motor in closed-loop mode with encoder feedback
Line current
35 A for 200 V 3 phases 5.5 kW / 7.5 hp 30.8 A for 240 V 3 phases 5.5 kW / 7.5 hp
Response time
R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s) R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s) AO1 2 ms, tolerance +/- 0.5 ms for analog output(s) <= 100 ms in STO (Safe Torque Off)
Apparent power
12.8 kVA at 240 V 3 phases 5.5 kW / 7.5 hp
Braking torque
30 % without braking resistor <= 150 % with braking or hoist resistor
Characteristic
Value(s)
Motor power hp
7.5 hp, 3 phases at 200...240 V
Motor power kW
5.5 kW, 3 phases at 200...240 V
Output voltage
<= power supply voltage
Linearity error
+/- 0.15 % of maximum value (AI1-/Al1+, AI2) +/- 0.2 % (AO1)
Torque accuracy
+/- 5 % in closed-loop mode with encoder feedback +/- 15 % in open-loop mode, without speed feedback
Local signalling
1 LED (red) for drive voltage
Range of product
Altivar Lift
Supply frequency
50...60 Hz - 5...5 %
Device short name
ATV71
Sampling duration
2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s) 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s) 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s) 2 ms +/- 0.5 ms (Al2) - analog input(s)
Tightening torque
3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Product destination
Synchronous motors Asynchronous motors
Analogue output type
AO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V 20 A
Discrete output type
Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Prospective line Isc
22 kA for 3 phases
Transient overtorque
170 %, +/- 10 % for 60 s 220 %, +/- 10 % for 2 s
Electrical connection
Terminal, clamping capacity: 2.5 mm², AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) Terminal, clamping capacity: 6 mm², AWG 8 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply voltage limits
170…264 V
Nominal output current
27.5 A at 4 kHz 230 V 3 phases 5.5 kW / 7.5 hp
Network number of phases
3 phases
Maximum switching current
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2) 2 A at 250 V AC on inductive load - cos phi = 0.4 -
Maximum transient current
37.4 A for 2 s 3 phases / 5.5 kW / 7.5 hp
Minimum switching current
3 mA at 24 V DC for configurable relay logic
Product or component type
Variable speed drive
[Us] rated supply voltage
200...240 V - 15...10 %
Communication port protocol
CANopen Modbus
Product specific application
Lift
Speed drive output frequency
0…599 Hz
type of cable for external connection
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC

Compatibility Information

Match ATV71LD27M3Z against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing ATV71LD27M3Z.

Maintenance Tips

Store ATV71LD27M3Z dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options