Product Description

Schneider Electric ATS48C59Y Product overview The Schneider Electric ATS48C59Y is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analogue output type: Current output AO 0-20 mA or 4-20 mA 500 Ohm - Characteristic: Value(s) - Communication Port Protocol: Modbus - Communication data link: Serial - Connector Type: 1 RJ45 - Depth: 11.8 in (300 mm) - Device connection: In the motor supply line - Device short name: ATS48 - Discrete input logic: Positive logic Stop, Run, LI3, LI4 < 5 V <= 2 mA > 11 V, >= 5 mA - Discrete input number: 5 - Discrete input type: PTC, 750 Ohm 77 °F (25 °C) Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm - Discrete output number: 2 - Discrete output type: LO1) logic output 0 V common configurable LO2) logic output 0 V common configurable R1) relay outputs fault relay NO R2) relay outputs end of starting relay NO R3) relay outputs motor powered NO - Function Available: External bypass (optional) - Height: 26.4 in (670 mm) - Marking: CE - Maximum Horse Power Rating: 150 hp 208 V for severe applications 200 hp 230 V for standard applications 350 hp 460 V for severe applications 400 hp 460 V for standard applications 400 hp 575 V for severe applications 500 hp 575 V for standard applications - Minimum switching current: 10 mA 6 V DC relay outputs - Motor power kW: 132 kW 230 V for severe applications 160 kW 230 V for standard applications 250 kW 400 V for severe applications 250 kW 440 V for severe applications 315 kW 400 V for standard applications 315 kW 500 V for severe applications 315 kW 525 V for severe applications 355 kW 440 V for standard applications 400 kW 500 V for standard applications 400 kW 525 V for standard applications 400 kW 660 V for severe applications 500 kW 690 V for severe applications 560 kW 660 V for standard applications 560 kW 690 V for standard applications - Operating position: Vertical +/- 10 degree - Physical interface: RS485 multidrop - Product Certifications: NOM 117 CSA GOST DNV CCC C-tick TCF UL SEPRO - Product Specific Application: Heavy duty industry and pumps - Product Weight: 113.3 lb(US) (51.4 kg) - Product destination: Asynchronous motors - Product or Component Type: Soft starter - Protection type: Phase failure line Thermal protection motor Thermal protection starter - Range of Product: Altistart 48 - Standards: IEC 60947-4-2 - Transmission Rate: 4800, 9600 or 19200 bps - Ue power supply voltage: 208...690 V - 15...10 % - Utilisation category: AC-53A - Width: 15.7 in (400 mm) - power supply frequency: 50...60 Hz - 5...5 % Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number ATS48C59Y with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
ATS48C59Y
Brand
Schneider Electric
Part Number
ATS48C59Y
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
11.8 in (300 mm)
Width
15.7 in (400 mm)
Height
26.4 in (670 mm)
Marking
CE
Packaging
New surplus, never used
Standards
IEC 60947-4-2
Characteristic
Value(s)
Connector Type
1 RJ45
Motor power kW
132 kW 230 V for severe applications 160 kW 230 V for standard applications 250 kW 400 V for severe applications 250 kW 440 V for severe applications 315 kW 400 V for standard applications 315 kW 500 V for severe applications 315 kW 525 V for severe applications 355 kW 440 V for standard applications 400 kW 500 V for standard applications 400 kW 525 V for standard applications 400 kW 660 V for severe applications 500 kW 690 V for severe applications 560 kW 660 V for standard applications 560 kW 690 V for standard applications
Product Weight
113.3 lb(US) (51.4 kg)
Protection type
Phase failure line Thermal protection motor Thermal protection starter
Range of Product
Altistart 48
Device connection
In the motor supply line
Device short name
ATS48
Transmission Rate
4800, 9600 or 19200 bps
Function Available
External bypass (optional)
Operating position
Vertical +/- 10 degree
Physical interface
RS485 multidrop
Discrete input type
PTC, 750 Ohm 77 °F (25 °C) Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
Product destination
Asynchronous motors
Analogue output type
Current output AO 0-20 mA or 4-20 mA 500 Ohm
Discrete input logic
Positive logic Stop, Run, LI3, LI4 < 5 V <= 2 mA > 11 V, >= 5 mA
Discrete output type
LO1) logic output 0 V common configurable LO2) logic output 0 V common configurable R1) relay outputs fault relay NO R2) relay outputs end of starting relay NO R3) relay outputs motor powered NO
Utilisation category
AC-53A
Discrete input number
5
Discrete output number
2
Product Certifications
NOM 117 CSA GOST DNV CCC C-tick TCF UL SEPRO
power supply frequency
50...60 Hz - 5...5 %
Communication data link
Serial
Ue power supply voltage
208...690 V - 15...10 %
Minimum switching current
10 mA 6 V DC relay outputs
Product or Component Type
Soft starter
Maximum Horse Power Rating
150 hp 208 V for severe applications 200 hp 230 V for standard applications 350 hp 460 V for severe applications 400 hp 460 V for standard applications 400 hp 575 V for severe applications 500 hp 575 V for standard applications
Communication Port Protocol
Modbus
Product Specific Application
Heavy duty industry and pumps

Compatibility Information

Match ATS48C59Y against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing ATS48C59Y.

Maintenance Tips

Store ATS48C59Y dry and dust-free in its packaging until installation.