Product Description
KEYENCE AP-V42WP
Product overview
The KEYENCE AP-V42WP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Accessories: End unit, head connection connector, extension warnings sticker
- Applicable sensor head: AP-41M, AP-41, AP-43, AP-44
- Control output: Maximum PNP open-collector output: 20 mA (30 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)
- Display: 4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18" ), AI indicator (green) Display cycle: 10 times/s
- Display resolution: AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg AP-43: Standard mode 0.01 kgf/cm 2 , High-resolution/Focus mode 0.02 Psi
- Display temperature characteristic: ±1 % of F.S. or less
- Eco mode: 12 V: 600 mW (50 mA) max., 24 V: 960 mW (40 mA) max.
- Environmental resistance / Ambient temperature: 0 to +50 °C 32 to 122 °F (No freezing)
- Hysteresis: Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable
- I/O / Zero-shift input: Input time: 2 ms or more (switchable with analog output)
- Material: Polycarbonate
- Operation indicator: Red LED × 2 (corresponding to control output 1 and control output 2)
- Power consumption / Normal: 12 V: 840 mW (70 mA) max., 24 V: 1,200 mW (50 mA) max.
- Rating / Power voltage: 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
- Relative humidity: 35 to 85 % RH (No condensation)
- Response time (Chattering prevention function): 1/2.5/5/100/500 ms (selectable
- Type: Amplifier Unit, PNP
- Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Weight: Approx. 80 g (with 2 m cable)
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number AP-V42WP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- AP-V42WP
- Brand
- KEYENCE
- Part Number
- AP-V42WP
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Amplifier Unit, PNP
- Weight
- Approx. 80 g (with 2 m cable)
- Display
- 4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18" ), AI indicator (green) Display cycle: 10 times/s
- Eco mode
- 12 V: 600 mW (50 mA) max., 24 V: 960 mW (40 mA) max.
- Material
- Polycarbonate
- Packaging
- New surplus, never used
- Hysteresis
- Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable
- Accessories
- End unit, head connection connector, extension warnings sticker
- Control output
- Maximum PNP open-collector output: 20 mA (30 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)
- Relative humidity
- 35 to 85 % RH (No condensation)
- Display resolution
- AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg AP-43: Standard mode 0.01 kgf/cm 2 , High-resolution/Focus mode 0.02 Psi
- Operation indicator
- Red LED × 2 (corresponding to control output 1 and control output 2)
- Vibration resistance
- 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Applicable sensor head
- AP-41M, AP-41, AP-43, AP-44
- I/O / Zero-shift input
- Input time: 2 ms or more (switchable with analog output)
- Rating / Power voltage
- 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
- Power consumption / Normal
- 12 V: 840 mW (70 mA) max., 24 V: 1,200 mW (50 mA) max.
- Display temperature characteristic
- ±1 % of F.S. or less
- Environmental resistance / Ambient temperature
- 0 to +50 °C 32 to 122 °F (No freezing)
- Response time (Chattering prevention function)
- 1/2.5/5/100/500 ms (selectable
Compatibility Information
Match AP-V42WP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing AP-V42WP.
Maintenance Tips
Store AP-V42WP dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. AP-V42WP is in stock and ships within 1-2 business days, with a tracking number for every shipment.
AP-V42WP is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match AP-V42WP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.