Product Description

Schneider Electric A9D47220 Product overview The Schneider Electric A9D47220 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 9 mm pitches: 4 - Breaking capacity: 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 - Characteristic: Value(s) - Comb busbar and distribution block compatibility: Top or bottom: YES Bottom: biconnect - Connection pitch: 9 mm between poles - Contact position indicator: No - Curve code: B - Depth: 78 mm - Device application: Distribution - Device location in system: Outgoer - Device short name: iC60 RCBO - Earth-leakage protection class: Type A-SI (Super Immunised) - Earth-leakage protection time delay: Instantaneous - Earth-leakage sensitivity: 30 mA - Height: 86 mm - Limitation class: 3 conforming to EN/IEC 61009-2-1 - Local signalling: ON, OFF, fault trip - Magnetic tripping limit: 3...5 x In - Mounting mode: Clip-on - Mounting support: DIN rail - Network frequency: 50 Hz - Network type: AC - Number of protected poles: 2 - Poles description: 2P - Product or component type: Residual current breaker with overcurrent protection (RCBO) - Quality labels: NF KEMA-KEUR IMQ VDE - Range: Acti9 - Rated breaking and making capacity: Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 - Residual current tripping technology: Voltage independent - Suitability for isolation: No conforming to IEC 60947-1 - Surge current: 3000 A - Trip unit technology: Thermal-magnetic - Width: 36 mm - [Ics] rated service breaking capacity: 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 - [In] rated current: 20 A - [Ue] rated operational voltage: 220...240 V AC 50 Hz - [Ui] rated insulation voltage: 500 V AC 50 Hz - [Uimp] rated impulse withstand voltage: 4 kV - control type: Toggle - product name: Acti9 iC60 RCBO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number A9D47220 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
A9D47220
Brand
Schneider Electric
Part Number
A9D47220
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
78 mm
Range
Acti9
Width
36 mm
Height
86 mm
Curve code
B
9 mm pitches
4
Network type
AC
control type
Toggle
product name
Acti9 iC60 RCBO
Mounting mode
Clip-on
Surge current
3000 A
Characteristic
Value(s)
Quality labels
NF KEMA-KEUR IMQ VDE
Connection pitch
9 mm between poles
Limitation class
3 conforming to EN/IEC 61009-2-1
Local signalling
ON, OFF, fault trip
Mounting support
DIN rail
Breaking capacity
10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Device short name
iC60 RCBO
Network frequency
50 Hz
Poles description
2P
Device application
Distribution
[In] rated current
20 A
Trip unit technology
Thermal-magnetic
Magnetic tripping limit
3...5 x In
Device location in system
Outgoer
Earth-leakage sensitivity
30 mA
Number of protected poles
2
Product or component type
Residual current breaker with overcurrent protection (RCBO)
Suitability for isolation
No conforming to IEC 60947-1
Contact position indicator
No
[Ui] rated insulation voltage
500 V AC 50 Hz
Earth-leakage protection class
Type A-SI (Super Immunised)
[Ue] rated operational voltage
220...240 V AC 50 Hz
Rated breaking and making capacity
Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Earth-leakage protection time delay
Instantaneous
Residual current tripping technology
Voltage independent
[Ics] rated service breaking capacity
7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
4 kV
Comb busbar and distribution block compatibility
Top or bottom: YES Bottom: biconnect

Compatibility Information

Match A9D47220 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing A9D47220.

Maintenance Tips

Store A9D47220 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options