Product Description

Schneider Electric 140CPU67261 Product overview The Schneider Electric 140CPU67261 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analogue I/O number: 500 inputs, 500 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 1984 inputs,1984 outputs - remote 0 - local - forbidden in Hot Standby application - Application specific I/O: Serial link Accurate time stamping High-speed interrupt inputs Counter - Application structure: 1 periodic fast task - forbidden in Hot Standby application 128 I/O interrupt tasks - forbidden in Hot Standby application 128 interrupt tasks - forbidden in Hot Standby application 32 timer interrupt tasks - forbidden in Hot Standby application 4 auxiliary tasks - forbidden in Hot Standby application 1 cyclic/periodic master task - - Bus current requirement: 2760 mA - Characteristic: Value(s) - Checks: Hot standby Process control - Clock frequency: 266 MHz - Communication Service: Ethernet router - Discrete I/O number: 31744 inputs, 31744 outputs - remote 8000 inputs, 8000 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 0 - local - forbidden in Hot Standby application - Electrical connection: 1 female connector SUB-D 9 for connecting to the Modbus Plus network 1 connector RJ45 for connecting Modbus bus 1 connector LC (single mode fiber optic) for interconnecting primary and secondary PLCs up to 16 km - Integrated connection type: 1 Modbus Plus 1 Modbus 1 USB 1 optic fibre Hot Standby - Local signalling: 1 LED (green) for Ethernet activity (COM) 1 LED (red) for Ethernet collision - Maximum number of connections: 1 USB 2 AS-Interface - distributed 4 AS-Interface - remote 6 Ethernet TCP/IP - local 6 Modbus Plus - local 6 Profibus DP - local 1 Modbus RS232/485 Modbus/ASCII) - Memory description: Expandable 7168 kB - program with PCMCIA card Expandable 8 MB - file storage with PCMCIA card Internal RAM 3072 kB - 1536 kB for data - Mode of Transmission: Single mode - Number of distributed I/O station: 63 1 3 Modbus Plus - Number of instructions per ms: 10.28 Kinst/ms 100 % Boolean 10.07 Kinst/ms 65 % Boolean and 35 % numerical - Number of optional modules: 6 Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) - Number of racks: 2 - local - Number of remote I/O station: 31 - 2 S908 remote I/O 31 - 2 ethernet Quantum remote I/O 31 - 2 ethernet X80 remote I/O - Number of slots: 16 10 6 2 4 - Product or Component Type: Unity processor - Range of Product: Modicon Quantum automation platform - Switch Function: Key switch memory port on/off - System overhead: 0.2 ms fast task 1 ms master task Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number 140CPU67261 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
140CPU67261
Brand
Schneider Electric
Part Number
140CPU67261
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Checks
Hot standby Process control
Packaging
New surplus, factory sealed original packaging
Characteristic
Value(s)
Clock frequency
266 MHz
Number of racks
2 - local
Number of slots
16 10 6 2 4
Switch Function
Key switch memory port on/off
System overhead
0.2 ms fast task 1 ms master task
Local signalling
1 LED (green) for Ethernet activity (COM) 1 LED (red) for Ethernet collision
Range of Product
Modicon Quantum automation platform
Memory description
Expandable 7168 kB - program with PCMCIA card Expandable 8 MB - file storage with PCMCIA card Internal RAM 3072 kB - 1536 kB for data
Analogue I/O number
500 inputs, 500 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 1984 inputs,1984 outputs - remote 0 - local - forbidden in Hot Standby application
Discrete I/O number
31744 inputs, 31744 outputs - remote 8000 inputs, 8000 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 0 - local - forbidden in Hot Standby application
Mode of Transmission
Single mode
Application structure
1 periodic fast task - forbidden in Hot Standby application 128 I/O interrupt tasks - forbidden in Hot Standby application 128 interrupt tasks - forbidden in Hot Standby application 32 timer interrupt tasks - forbidden in Hot Standby application 4 auxiliary tasks - forbidden in Hot Standby application 1 cyclic/periodic master task -
Communication Service
Ethernet router
Electrical connection
1 female connector SUB-D 9 for connecting to the Modbus Plus network 1 connector RJ45 for connecting Modbus bus 1 connector LC (single mode fiber optic) for interconnecting primary and secondary PLCs up to 16 km
Bus current requirement
2760 mA
Application specific I/O
Serial link Accurate time stamping High-speed interrupt inputs Counter
Product or Component Type
Unity processor
Integrated connection type
1 Modbus Plus 1 Modbus 1 USB 1 optic fibre Hot Standby
Number of optional modules
6 Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
Number of remote I/O station
31 - 2 S908 remote I/O 31 - 2 ethernet Quantum remote I/O 31 - 2 ethernet X80 remote I/O
Maximum number of connections
1 USB 2 AS-Interface - distributed 4 AS-Interface - remote 6 Ethernet TCP/IP - local 6 Modbus Plus - local 6 Profibus DP - local 1 Modbus RS232/485 Modbus/ASCII)
Number of instructions per ms
10.28 Kinst/ms 100 % Boolean 10.07 Kinst/ms 65 % Boolean and 35 % numerical
Number of distributed I/O station
63 1 3 Modbus Plus

Compatibility Information

Match 140CPU67261 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing 140CPU67261.

Maintenance Tips

Store 140CPU67261 dry and dust-free in its packaging until installation.